Watts to Lux Estimate from Luminous Efficacy — result sheet
Estimate illuminance from electrical power, a supplied luminous efficacy, utilization factor, and illuminated area.
Inputs used
Results
Visual chart
Breakdown
Calculation steps
Returned data table
Formula and methodology
Formula: Nominal lumens = electrical watts × luminous efficacy; usable lumens = nominal lumens × utilization; average illuminance = usable lumens ÷ area in m².
Watts alone do not determine lux: electrical power must be paired with a luminous-efficacy assumption, and illuminance also depends on how much light reaches the target area. This estimate makes both inputs visible and reports nominal lumens, usable lumens, average lux, and foot-candles. It does not model spectrum, beam angle, distance, reflectance, glare, room geometry, fixture optics, dimming, or a photometric measurement.
This result follows the calculator's declared inputs, precision, validation boundaries, and model limits.
Input contract
- Electrical power — W; minimum 1.0E-6; maximum 1000000000
- Luminous efficacy — lm/W; minimum 1.0E-6; maximum 683
- Illuminated area — m²; minimum 1.0E-6; maximum 1000000000
- Utilization reaching the area — %; minimum 0; maximum 100
Worked example
| Input | Value |
|---|---|
| Electrical power | 40 |
| Luminous efficacy | 100 |
| Illuminated area | 10 |
| Utilization reaching the area | 80 |
40 W at 100 lm/W gives 4,000 nominal lumens; with 80% utilization over 10 m² the estimate is 3,200 usable lumens, 320 lux, or about 29.73 foot-candles.
Assumptions and limits
- Electrical power is converted to nominal luminous flux using the entered efficacy in lumens per watt.
- The efficacy is an effective source/system value, not automatically the 683 lm/W monochromatic maximum.
- Utilization is a simple fraction of nominal lumens reaching the entered area.
- Illuminance is averaged uniformly over the area and one lux equals one lumen per square metre.
- No inverse-square point-source model, fixture distribution, spectral weighting, reflectance, or maintenance loss is inferred.
- The result is a planning estimate and not a lighting-code compliance, plant-lighting, or safety claim.