Vapor Pressure Deficit Calculator — result sheet
Estimate saturation vapor pressure, actual vapor pressure, and vapor pressure deficit from air temperature and relative humidity using a transparent FAO-style approximation.
Inputs used
Results
Visual chart
Breakdown
Calculation steps
Returned data table
Formula and methodology
Formula: Saturation vapor pressure e_s = 0.6108 × exp(17.27T ÷ (T + 237.3)) kPa; actual vapor pressure e_a = e_s × RH ÷ 100; VPD = e_s − e_a.
Vapor pressure deficit describes the difference between saturation vapor pressure and actual vapor pressure at the entered temperature. This page uses a single-temperature and mean-relative-humidity approximation for planning and teaching; daily FAO-56 calculations can instead use maximum and minimum temperatures, humidity, dew point, wind, and radiation.
This result follows the calculator's declared inputs, precision, validation boundaries, and model limits.
Input contract
- Air temperature — °C; minimum -80; maximum 70
- Relative humidity — %; minimum 0; maximum 100
Worked example
| Input | Value |
|---|---|
| Air temperature | 25 |
| Relative humidity | 50 |
At 25 °C and 50% relative humidity, saturation vapor pressure is about 3.168 kPa, actual vapor pressure is about 1.584 kPa, and VPD is about 1.584 kPa.
Assumptions and limits
- Temperature is entered in degrees Celsius and the saturation-pressure approximation is evaluated over the bounded input range.
- Relative humidity is entered as a percentage from 0 to 100.
- The calculation uses the FAO-style saturation vapor pressure relation over water and does not switch to an ice-surface equation below freezing.
- Actual vapor pressure is estimated as saturation vapor pressure multiplied by mean relative humidity.
- The result is an air-humidity metric and does not calculate evapotranspiration, irrigation demand, plant stress, or a crop-specific target.
- Measurements, sensor placement, time of day, and averaging period can materially change a real VPD value.
Calculator note
Source and methodology
Use the official WorldCalculate methodology policy for the source, formula, precision, and boundary standards behind this calculator.