Download your Word document
Energy Use Intensity (EUI) Calculator result sheet — free, supported by sponsors. Your download button appears in 20 seconds.
This free download is supported by sponsors — continuing in
20
Your file is generated in your browser when you choose Download — nothing is uploaded. If this calculator returns enough numeric data, the export also includes its best-fit chart alongside the readable table.
WorldCalculate result export
Energy Use Intensity (EUI) Calculator — result sheet
Calculate a building’s annual energy use intensity from total annual energy, floor area, and globally usable energy and area units.
Inputs used
Results
Visual chart
Breakdown
Calculation steps
Returned data table
Formula and methodology
Formula: EUI = annual energy use ÷ gross floor area. The page also converts the result to kWh/m²/year and kBtu/ft²/year for comparison.
Energy use intensity normalizes a building’s annual energy by its floor area. The normalization makes different-sized buildings easier to compare, while the energy boundary, weather, occupancy, property type, and source-versus-site definition still determine what a comparison means.
This result follows the calculator's declared inputs, precision, validation boundaries, and model limits.
Input contract
- Annual energy use — selected unit; minimum 1.0E-6; maximum 1000000000000000000
- Energy unit — 5 choices
- Gross floor area — selected unit; minimum 1.0E-6; maximum 1000000000000000
- Area unit — 2 choices
Worked example
| Input | Value |
|---|---|
| Annual energy use | 200000 |
| Energy unit | kBtu |
| Gross floor area | 10000 |
| Area unit | ft2 |
The entered-unit EUI is 20 kBtu/ft²/year, equivalent to about 63.09 kWh/m²/year.
Assumptions and limits
- Annual energy is the total for the stated reporting period and the floor area is the gross area used for the intended comparison.
- The selected energy and area units are converted before standardized outputs are calculated.
- The tool does not decide whether the supplied energy is site energy or source energy.
- One year is represented by the annual input; monthly, seasonal, and weather-normalized adjustments are not inferred.
- The result is not a regulatory compliance score, ENERGY STAR score, building label, or engineering diagnosis.
- Worldwide users should use local meter records and the local benchmark or reporting convention relevant to the property.
Calculator note
Source and methodology
Use the official WorldCalculate methodology policy for the source, formula, precision, and boundary standards behind this calculator.
Planning estimate, not financial, medical, legal, or professional advice. © WorldCalculate — reuse with attribution. Built and curated by Hassan ALRowaie.