Simplified Circuit Breaker Load Estimate — result sheet
Estimate a planning minimum overcurrent-device rating from continuous and noncontinuous loads, then round to a common standard rating.
Inputs used
Results
Visual chart
Breakdown
Calculation steps
Returned data table
Formula and methodology
Formula: Planning design current = noncontinuous current + 1.25 × continuous current; suggested standard rating = the first common rating not below that result.
This calculator makes a common continuous-load planning convention visible instead of hiding it in a single answer. It reports the unrounded design current, a suggested standard rating, and the approximate 80% continuous-load capacity of that rating. It is an educational planning estimate, not a code-compliance decision or permission to select a breaker without checking the jurisdiction, conductor ampacity, equipment listing, fault level, temperature, installation method, and motor or HVAC rules.
This result follows the calculator's declared inputs, precision, validation boundaries, and model limits.
Input contract
- Continuous load — A; minimum 1.0E-6; maximum 1000000
- Noncontinuous load — A; minimum 1.0E-6; maximum 1000000
Worked example
| Input | Value |
|---|---|
| Continuous load | 16 |
| Noncontinuous load | 8 |
The simplified design current is 28 A; the next rating in the generic list is 30 A, whose nominal 80% continuous capacity is 24 A.
Assumptions and limits
- The continuous-load factor is fixed at 125% for this simplified planning model.
- The noncontinuous portion is counted at 100% and the two entered loads are already expressed as currents on the same basis.
- The suggested ratings are a generic rounded list and are not a complete national or manufacturer rating table.
- No conductor ampacity, ambient-temperature correction, bundling, voltage drop, interrupting rating, equipment listing, or fault-current study is modeled.
- Motor, HVAC, service, dwelling, healthcare, solar, and other special rules can change the required design and are outside this page.
- A licensed or qualified person must verify the result against the rules and equipment used at the installation.